VPI HW-19 MK-4 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Plateau tournant VPI HW-19 MK-4. HW-19 MK-3 - VPI Industries Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 8
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
1
PRELIMINARY REMARKS
Save the carton and all internal fillers and plastic bags. If you should ever need to
carry or ship the HW-19 Mk. 111 any distance, there is much less chance of it
suffering damage in transit if it is properly packed in its original carton.
Electrical Requirements: HW-19’s are designed to run on 115 VAC 60 Hz, or 230
VAC 50 Hz. The shipping carton shows which is the correct voltage for your unit.
CAUTION: TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS UNIT TO
RAIN OR MOISTURE.
1. UNPACKING
1.1 Remove the corrugated sheet on which these instructions were lying. You will
see plastic bags with contents as follows:
A- 4- Rubber feet
B- Drive belt (with white powder)
C- Record clamp (black knob), 1 ¼” rubber washer, 3 3/8” plastic puck
1.2 Take out the three bags and put them aside. Remove large foam sheet and small
pieces. You will now see the dust cover (with hinges attached) in its plastic bag.
Lift out the cover and set it aside for now in a safe place.
1.3 Remove the corrugated sheet on which the cover was lying. The turntable’s main
chassis is now visible. Remove the white foam pieces and lift out the main
chassis. Be prepared for considerable weight.
1.4 Set the chassis on its side leaning against the shipping carton or other suitable
object. If you lean it against a piece of furniture or a wall, be careful that the
edge of the chassis does not scratch it.
NOTE: Be very careful not to turn the chassis upside-down. The spindle will fall out
and be damaged. Also, never rest the chassis either on the spindle or on the bearing
well, which protrudes beneath the chassis.
1.5 Once again, there is a corrugated sheet to remove. Do so and you will see the
HW-19 Mk.-3’s base.
1.6 Take the base out of the carton by grasping it on opposite sides and lifting
straight up. The four plastic corner blocks should fall off into the carton. If any
remain on the base, take them off and set them aside. They should be kept
along with all the other fillers.
1.7 Place the base straddling two sturdy chairs of the same height. This will give you
access to the top and bottom of the turntable during assembly. Now, remove the
plastic bag from the base.
1.8 CAUTIONS:
1. Be careful not to damage the pulley and motor shaft.
2. Watch out for the line cord.
3. Be careful not to dislodge any of the coil springs at the base’s four corners.
NOTE: The hinge holders on the rear of the base are normally loose to allow the dust
cover to be attached. They will be tightened later on.
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1 - 1. UNPACKING

1 PRELIMINARY REMARKS  Save the carton and all internal fillers and plastic bags. If you should ever need to carry or ship the HW-19 Mk. 11

Page 2

2 1.9 The last item in the carton is the turntable platter. Leave it in place until it is needed later. 2. ASSEMBLING THE HW-19 MK-3 YOU

Page 3 - 3. MOUNTING THE TONEARM

3 tighten the clamp, it will press the platter evenly onto the spindle, seating it fully. Make the clamp very tight but don’t overdo it. Leave the

Page 4 - 4. LEVELING THE HW-19 MK-3

4 3.6 Fasten the arm board to the chassis with the six screws. Make sure that there is a washer under each screw head. Tighten each screw well. 3.

Page 5

5 However, if you do want to be a fanatic, put a bubble level on the platter. Center the bubble by rotating the base’s rubber feet to raise

Page 6 - 9. POSSIBLE PROBLEMS

6 7.6 Finally, take the knurled clamp and screw it down (flat side down) over the puck. Tighten it enough that the periphery of the record is broug

Page 7 - 10. MAINTENANCE

7 cartridge/arm/turntable problem. Usually all that is needed to eliminate the hum is to run a ground wire from the turntable chassis to the chassis

Page 8

8 an extremely thin layer, degrading electrical contacts. Once a contact has been contaminated with silicone, it is nearly impossible to clean it co

Commentaires sur ces manuels

Pas de commentaire